{"product_id":"45m-sc-sc-os1-os2-duplex-patch-lead","title":"45M SC-SC OS1\/OS2 Duplex Patch Lead","description":"\u003cp data-start=\"328\" data-end=\"731\"\u003eThe \u003cstrong data-start=\"332\" data-end=\"376\"\u003e45 metre SC-SC OS1\/OS2 Duplex Patch Lead\u003c\/strong\u003e is a high-performance single-mode fibre optic cable designed for reliable, low-loss connectivity between network devices. Equipped with \u003cstrong data-start=\"513\" data-end=\"535\"\u003edual SC connectors\u003c\/strong\u003e on each end and compliant with \u003cstrong data-start=\"567\" data-end=\"578\"\u003eOS1\/OS2\u003c\/strong\u003e fibre standards, this patch lead delivers superior signal integrity and minimal attenuation, making it ideal for long-distance single-mode applications.\u003c\/p\u003e\n\u003cp data-start=\"733\" data-end=\"1261\"\u003eConstructed with a robust duplex cable and precision-polished SC connectors, this lead provides stable optical performance in data centres, telecommunications, FTTH networks, and enterprise infrastructure. The duplex configuration supports bidirectional data transmission on two fibres, while the durable outer jacket protects the cable against bending and environmental factors. With its 40 m length, this patch lead is ideal for linking patch panels, switches, ODFs, and optical equipment across medium to large installations.\u003c\/p\u003e\n\u003chr data-end=\"1266\" data-start=\"1263\"\u003e\n\u003cp\u003e\u003cstrong data-start=\"1273\" data-end=\"1289\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1292\" data-end=\"1337\"\u003e\n\u003cstrong data-start=\"1292\" data-end=\"1304\"\u003e45 metre\u003c\/strong\u003e single-mode duplex fibre cable\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1398\"\u003e\n\u003cstrong data-start=\"1340\" data-end=\"1349\"\u003eSC-SC\u003c\/strong\u003e connectors — quick push\/pull locking mechanism\u003c\/li\u003e\n\u003cli data-start=\"1401\" data-end=\"1453\"\u003eCompliant with \u003cstrong data-start=\"1416\" data-end=\"1427\"\u003eOS1\/OS2\u003c\/strong\u003e optical fibre standards\u003c\/li\u003e\n\u003cli data-start=\"1456\" data-end=\"1510\"\u003eLow \u003cstrong data-start=\"1460\" data-end=\"1478\"\u003einsertion loss\u003c\/strong\u003e and excellent \u003cstrong data-start=\"1493\" data-end=\"1508\"\u003ereturn loss\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1560\"\u003eDuplex design for bidirectional communication\u003c\/li\u003e\n\u003cli data-start=\"1563\" data-end=\"1626\"\u003ePrecision polished connector endfaces for high signal quality\u003c\/li\u003e\n\u003cli data-start=\"1629\" data-end=\"1676\"\u003eRobust outer jacket for mechanical protection\u003c\/li\u003e\n\u003cli data-start=\"1679\" data-end=\"1721\"\u003eSuitable for indoor cabling environments\u003c\/li\u003e\n\u003cli data-start=\"1724\" data-end=\"1776\"\u003eCompatible with telecom, data and LAN\/WAN networks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1781\" data-start=\"1778\"\u003e\n\u003cp\u003e\u003cstrong data-start=\"1789\" data-end=\"1807\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable data-start=\"1809\" data-end=\"3040\"\u003e\n\u003cthead data-start=\"1809\" data-end=\"1891\"\u003e\n\u003ctr data-start=\"1809\" data-end=\"1891\"\u003e\n\u003cth data-start=\"1809\" data-end=\"1845\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1811\" data-end=\"1824\"\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1845\" data-end=\"1891\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1847\" data-end=\"1864\"\u003eValue \/ Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1974\" data-end=\"3040\"\u003e\n\u003ctr data-start=\"1974\" data-end=\"2055\"\u003e\n\u003ctd data-start=\"1974\" data-end=\"2009\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1976\" data-end=\"1992\"\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2009\" data-end=\"2055\" data-col-size=\"sm\"\u003e45 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2056\" data-end=\"2137\"\u003e\n\u003ctd data-start=\"2056\" data-end=\"2091\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2058\" data-end=\"2073\"\u003eConnector A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2091\" data-end=\"2137\" data-col-size=\"sm\"\u003eSC (Duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2138\" data-end=\"2219\"\u003e\n\u003ctd data-start=\"2138\" data-end=\"2173\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2140\" data-end=\"2155\"\u003eConnector B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2173\" data-end=\"2219\" data-col-size=\"sm\"\u003eSC (Duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2220\" data-end=\"2301\"\u003e\n\u003ctd data-start=\"2220\" data-end=\"2255\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2222\" data-end=\"2236\"\u003eFibre Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2255\" data-end=\"2301\" data-col-size=\"sm\"\u003eSingle-mode OS1\/OS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2302\" data-end=\"2383\"\u003e\n\u003ctd data-start=\"2302\" data-end=\"2337\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2304\" data-end=\"2321\"\u003eCore Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2337\" data-end=\"2383\" data-col-size=\"sm\"\u003e9 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2384\" data-end=\"2464\"\u003e\n\u003ctd data-start=\"2384\" data-end=\"2418\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2386\" data-end=\"2407\"\u003eCladding Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2418\" data-end=\"2464\" data-col-size=\"sm\"\u003e125 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2465\" data-end=\"2546\"\u003e\n\u003ctd data-start=\"2465\" data-end=\"2500\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2467\" data-end=\"2487\"\u003eWavelength Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2500\" data-end=\"2546\" data-col-size=\"sm\"\u003e1310 nm \/ 1550 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2547\" data-end=\"2629\"\u003e\n\u003ctd data-start=\"2547\" data-end=\"2582\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2549\" data-end=\"2577\"\u003eInsertion Loss (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2629\" data-col-size=\"sm\"\u003e≤ 0.3 dB per mated pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2630\" data-end=\"2711\"\u003e\n\u003ctd data-start=\"2630\" data-end=\"2665\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2632\" data-end=\"2647\"\u003eReturn Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2665\" data-end=\"2711\" data-col-size=\"sm\"\u003e≥ 50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2712\" data-end=\"2793\"\u003e\n\u003ctd data-start=\"2712\" data-end=\"2747\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2714\" data-end=\"2730\"\u003eCable Jacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2747\" data-end=\"2793\" data-col-size=\"sm\"\u003eLSZH \/ PVC (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2794\" data-end=\"2875\"\u003e\n\u003ctd data-start=\"2794\" data-end=\"2829\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2796\" data-end=\"2821\"\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2829\" data-end=\"2875\" data-col-size=\"sm\"\u003e–20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2876\" data-end=\"2958\"\u003e\n\u003ctd data-start=\"2876\" data-end=\"2911\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2878\" data-end=\"2901\"\u003eMinimum Bend Radius\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2911\" data-end=\"2958\" data-col-size=\"sm\"\u003e≥ 10 × cable diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2959\" data-end=\"3040\"\u003e\n\u003ctd data-start=\"2959\" data-end=\"2994\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2961\" data-end=\"2975\"\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2994\" data-end=\"3040\" data-col-size=\"sm\"\u003eRoHS, IEC, ISO\/IEC standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr data-end=\"3045\" data-start=\"3042\"\u003e\n\u003cp\u003e\u003cstrong data-start=\"3053\" data-end=\"3069\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eData centres and server rooms\u003c\/li\u003e\n\u003cli data-start=\"3165\" data-end=\"3206\"\u003eTelecommunications and ISP networks\u003c\/li\u003e\n\u003cli data-start=\"3209\" data-end=\"3239\"\u003eFTTH\/OLT\/ONT connections\u003c\/li\u003e\n\u003cli data-start=\"3242\" data-end=\"3278\"\u003eLAN\/WAN optical backbone links\u003c\/li\u003e\n\u003cli data-start=\"3281\" data-end=\"3320\"\u003eOptical distribution frames (ODF)\u003c\/li\u003e\n\u003cli data-start=\"3323\" data-end=\"3364\"\u003eOptical test and measurement setups\u003c\/li\u003e\n\u003cli data-start=\"3367\" data-end=\"3411\"\u003ePatch panels and switch interconnections\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GROVE","offers":[{"title":"Default Title","offer_id":45888810451129,"sku":"LF-GNSCSC45DX","price":50.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0567\/9893\/7273\/files\/https_1pd.net.au_products_45m-sc-sc-os1-os2-duplex-patch-lead.jpg?v=1772333523","url":"https:\/\/1pd.net.au\/products\/45m-sc-sc-os1-os2-duplex-patch-lead","provider":"1 Point Distribution","version":"1.0","type":"link"}